| Article name | NRF | NOBB | Recess | Frame | Light opening | Weight | Antall | Legg i liste |
|---|---|---|---|---|---|---|---|---|
| Article name: UP-FS60-020020F | NRF: UP-FS60F | NOBB: 60045999 | Recess: 205 x 205 | Frame: 200 x 200 | Light opening: 195 x 195 | Weight: 1.6 kg | ||
| Article name: UP-FS60-030030F | NRF: UP-FS60F | NOBB: 60046000 | Recess: 305 x 305 | Frame: 300 x 300 | Light opening: 295 x 295 | Weight: 3.5 kg | ||
| Article name: UP-FS60-040040F | NRF: UP-FS60F | NOBB: 60046001 | Recess: 405 x 405 | Frame: 400 x 400 | Light opening: 395 x 395 | Weight: 5.9 kg | ||
| Article name: UP-FS60-040060F | NRF: UP-FS60F | NOBB: 60046002 | Recess: 405 x 605 | Frame: 400 x 600 | Light opening: 395 x 595 | Weight: 8.4 kg | ||
| Article name: UP-FS60-050050F | NRF: UP-FS60F | NOBB: 60046003 | Recess: 505 x 505 | Frame: 500 x 500 | Light opening: 495 x 495 | Weight: 8.9 kg | ||
| Article name: UP-FS60-060060F | NRF: UP-FS60F | NOBB: 60046004 | Recess: 605 x 605 | Frame: 600 x 600 | Light opening: 595 x 595 | Weight: 12.7 kg | ||
| Article name: UP-FS60-060080F | NRF: UP-FS60F | NOBB: 60046005 | Recess: 605 x 805 | Frame: 600 x 800 | Light opening: 595 x 795 | Weight: 17.6 kg |
Description
Fire hatch with square lock for use in walls. Used in plasterboard and concrete wall for:
• Quick access to pipes, fittings, valves, and electrical connections.
• The frame has an 18 mm surface-mounted flange that will hide any irregularities in the recess.
Varnishing:
White powder coated RAL 9016.
Change of RAL code at extra cost.
Materials:
• Galvanized steel in frame and lid.
• Supplied control key in PP.
Insulation:
The hatch is delivered fire-insulated EI60.
Operation:
Opening and closing takes place by 90 º turning with the key.
Assembly:
• Perpendicular holes are cut in the wall/ceiling according to the recess dimensions in the table.
• To ensure good sealing between the flange and the wall surface, it is recommended to lay a string of sealant ACRYL-1A on the frame flange itself before installing the frame.
• Wooden or steel posts are used on at least two of the sides of the frame.
• 4 anchors for attaching the frame are for the drill with 5 holes. The anchors are rotated 90 ° out of the frame and fastened to posts.
• In concrete constructions, expansion bolts must be used for fastening the frame.
• There is no need to line the opening, but good sealing must be ensured between the concrete and the frame.
• Installation instructions are included with each individual hatch.
Recess dimensions are 5 mm larger than frame dimensions. Insert in wall is 54 mm.
Light opening = Final opening with installed hatch.
Maximum size: 600 x 800 mm