Fire Hatch With Square Lock. EI60. Type: UP-FS60F

Fire-insulated inspection hatch with square lock. EI60. For wall use. Soundproofing – 26 dB.

SKU: N/A Category:

Varianter

Article nameNRFNOBBRecessFrameLight openingWeightAntallLegg i liste
Article name: UP-FS60-020020FNRF: UP-FS60FNOBB: 60045999Recess: 205 x 205Frame: 200 x 200Light opening: 195 x 195Weight: 1.6 kg
Article name: UP-FS60-030030FNRF: UP-FS60FNOBB: 60046000Recess: 305 x 305Frame: 300 x 300Light opening: 295 x 295Weight: 3.5 kg
Article name: UP-FS60-040040FNRF: UP-FS60FNOBB: 60046001Recess: 405 x 405Frame: 400 x 400Light opening: 395 x 395Weight: 5.9 kg
Article name: UP-FS60-040060FNRF: UP-FS60FNOBB: 60046002Recess: 405 x 605Frame: 400 x 600Light opening: 395 x 595Weight: 8.4 kg
Article name: UP-FS60-050050FNRF: UP-FS60FNOBB: 60046003Recess: 505 x 505Frame: 500 x 500Light opening: 495 x 495Weight: 8.9 kg
Article name: UP-FS60-060060FNRF: UP-FS60FNOBB: 60046004Recess: 605 x 605Frame: 600 x 600Light opening: 595 x 595Weight: 12.7 kg
Article name: UP-FS60-060080FNRF: UP-FS60FNOBB: 60046005Recess: 605 x 805Frame: 600 x 800Light opening: 595 x 795Weight: 17.6 kg

Description

Fire hatch with square lock for use in walls. Used in plasterboard and concrete wall for:

• Quick access to pipes, fittings, valves, and electrical connections.

• The frame has an 18 mm surface-mounted flange that will hide any irregularities in the recess.

Varnishing:

White powder coated RAL 9016.

Change of RAL code at extra cost.

Materials:

• Galvanized steel in frame and lid.

• Supplied control key in PP.

Insulation:

The hatch is delivered fire-insulated EI60.

Operation:

Opening and closing takes place by 90 º turning with the key.

Assembly:

• Perpendicular holes are cut in the wall/ceiling according to the recess dimensions in the table.

• To ensure good sealing between the flange and the wall surface, it is recommended to lay a string of sealant ACRYL-1A on the frame flange itself before installing the frame.

• Wooden or steel posts are used on at least two of the sides of the frame.

• 4 anchors for attaching the frame are for the drill with 5 holes. The anchors are rotated 90 ° out of the frame and fastened to posts.

• In concrete constructions, expansion bolts must be used for fastening the frame.

• There is no need to line the opening, but good sealing must be ensured between the concrete and the frame.

• Installation instructions are included with each individual hatch.

Recess dimensions are 5 mm larger than frame dimensions. Insert in wall is 54 mm.

Light opening = Final opening with installed hatch.

Maximum size: 600 x 800 mm